with condensing water at

degrees

Fahr.
Cent.

}

feed pump(s) of standard Pump(s) and

219. Feed Injector(s).

manufacture (each) having ample capacity

to feed h. p. in boilers.

220. FeedWater Heater (s) and

feed-water heater(s) [and purifier(s)] of standard manufacture (each) Purifier(s). having ample capacity for-h. p. in boil

ers.

(Specify character of water to be used, and whether exhaust steam is to be used for any other purpose than heating feedwater.)

ure.

separator(s) of standard manufact- 221. Separa

tor(s).

Board.

A gauge board of — shall be erected 222. Gauge in, and the following instruments

mounted thereon:

Connections

shall be made between these instruments

and in the following manner —

223. Painting.

224. Renewal Parts

225. Summary.

(As required.)

Such renewal parts as it is advisable to have on hand shall be furnished, a list of same to be added hereto.

(See Note: p. 52, sec. 27.)

Each bidder shall fill out completely the following summary:

[merged small][merged small][merged small][merged small][ocr errors][ocr errors][merged small][merged small][ocr errors][merged small][merged small][merged small]

Kind

Capacity of each

Number of heaters

Kind

Capacity of each

RULES AND REQUIREMENTS

OF THE

NATIONAL BOARD OF FIRE UNDERWRITERS FOR THE INSTALLATION OF WIRING AND APPARATUS FOR ELECTRIC LIGHT AND POWER AS RECOMMENDED BY THE UNDERWRITERS'

NATIONAL ELECTRIC ASSOCIATION.

EDITION OF JAN. 1, 1895.

The use of wire ways for rendering concealed wiring permanently accessible, is most heartily endorsed and recommended; and this method of accessible concealed construction is advised for general use.

Architects are urged, when drawing plans and specifications, to make provision for the channeling and pocketing of buildings for electric light or power wires, and in specifications for electric gas lighting to require a two-wire circuit, whether the building is to be wired for electric lighting or not, so that no part of the gas fixtures or gas piping be allowed to be used for the gas lighting circuit.

CENTRAL STATIONS.

Class A.

FOR LIGHT OR POWER.

These Rules also apply to Dynamo Rooms in Isolated Plants, connected with or detached from buildings used for other purposes; also to all varieties of apparatus therein of both high and low potential. 1. GENERATORS:

a. Must be located in a dry place.

b. Must be insulated on floors or base-frames, which must be kept filled, to prevent absorption of moisture, and also kept clean and dry.

c. Must never be placed in a room where any hazardous process is carried on, more in places where they would be exposed to inflammable gases, or flyings, or combustible material.

d. Must each be provided with a waterproof covering.

2. CARE AND ATTENDANCE:

A competent man must be kept on