Three-Wire System Adapted to the Two-
Wire System.

This specification is identical with the two-wire specification, except in '.' System," p. 94, sec. 84, in place of which insert the following:

of three wires, but the neutral wire shall consist of two wires each equal in cross-section to the outside wires, or of one wire equal in cross-section to the

desired all lights may be operated on the two-wire system; if two neutral wires are run they shall be permanently connected at each cut-out box. All distribution circuits shall consist of two wires only

except to outlets for a group of ,

c. p., lamps or more, and for special circuits specifically mentioned. In all three

[merged small][graphic][merged small][graphic][merged small]

outside wires combined, in order that if wire distribution circuits the neutral shall be equal in cross-section to the two outside wires combined. Care shall be taken in arranging the distribution circuits to have the same number of lamps on each side of the system and that no circuit shall be connected across the outside wires or between the neutral wires. The neutral shall in all cases be properly tagged and shall be run between the outside wires.

Arc System.

108. circuits. The lights shall be divided into the following circuits:

Circuit No. 1 (Number of lights and location.)

Circuit No. 2 (Number of lights and location), etc.

ttonoiwirt" All wire used in the installation shall

be insulated with for inside circuits,

and with for outside circuits.

"ion ^siatt- Each circuit shall test out with an inance" sulation resistance of at least ohms.

in. joints. See p. 97, sec. 92.

ii2-wMethod £\\ interior wires shall be run

| in iondufts1"8 [in such a manner that the highest possible insulation is obtained. All wiring shall be neat in its mechanical appearance and arrangement. All exterior wires shall be run .

In the interior of (the) building(s) the H3. Suspenlamps specified shall be suspended from

securely fastened to the ceiling (and

provided with a suitable device for raising and lowering). On the exterior of (the) building(s) the lamps specified shall be

suspended from , securely attached to

, (and provided with a suitable device

for raising and lowering).

(Add details concerning any posts, pole-steps, ornamental treatment desired, etc.)

Conduit System. Two- Wire.

"VSSS-01 The building shall be wired according to the system of and using the

conduit manufactured by .

115;„cAa.pU- All appliances employed shall be such as are especially adapted for use in conjunction with the conduit system.

or condfitef All conduits shall be placed in position | after6 [ ^e Plas^erm§ *s done, and shall be firmly secured j ^j^in [ wa^s and ceilings.

"openings118 After the tubes are installed all openings in walls and floors shall be sealed so that it shall be impossible, in the event of fire, for smoke or flame to pass from one floor to another or from one room to another about the tubes.