" Water meters, as a rule, should only be used as a check on other measurements. For accurate work, the water should be weighed or measured in a tank. 3. Thermometers and pyrometers for taking temperatures of air, steam, feedwater, waste gases, etc. "
Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ... - Сторінка 878
автори: Horatio Alvah Foster - 1901 - 987 стор.
Повний перегляд - Докладніше про цю книгу

Van Nostrand's Engineering Magazine, Том 32

1885 - 566 стор.
...ashes and water. 2. Tanks, or water meters for measuring water. Water meters as a rule should only be used as a check on other measurements. For accurate...the water should be weighed or measured in a tank. (Appendix VI. and VII.) 3. Thermometers and pyrometers lor taking temperatures of air, steam, feed-water,...
Повний перегляд - Докладніше про цю книгу

Transactions, Том 6

American Society of Mechanical Engineers - 1885 - 984 стор.
...ashes, and water. 2. Tanks, or water meters for measuring water. Water meters, as a rule should only be used as a check on other measurements. For accurate...the water should be weighed or measured in a tank. (Appendix VI. and VII.) 3. Thermometers and pyrometers for taking temperatures of air, steam, feed-water,...
Повний перегляд - Докладніше про цю книгу

A Manual of Steam-boilers: Their Design, Construction, and Operation

Robert Henry Thurston - 1888 - 710 стор.
...and water. 2. Tanks, or water-meters for measuring water. Water, meters, as a rule, should only be used as a check on other measurements. For accurate...temperatures of air, steam, feed-water, waste gases, etc. 4. Pressure-gauges, draught-gauges, etc. VII. Before beginning a test, the boiler and chimney should be...
Повний перегляд - Докладніше про цю книгу

A Treatise on Steam-boiler: Their Strength, Construction, and Economical Working

Robert Wilson - 1889 - 492 стор.
...coal, ashes, and water. 2. Tanks or water-meters for measuring water. WTater-meters as a rule should be used as a check on other measurements. For accurate...feed-water, waste gases, etc. 4. Pressure gauges, draught gauges, etc. VII. Before beginning a test the boiler and chimney should be thoroughly heated...
Повний перегляд - Докладніше про цю книгу

A Treatise on Steam-boilers: Their Strength, Construction, and Economical ...

Robert Wilson - 1889 - 490 стор.
...coal, ashes, and water. a. Tanks or water-meters for measuring water. Water-meters as a rule should be used as a check on other measurements. For accurate...pyrometers for taking temperatures of air, steam, feed- water, waste gases, etc. 4. Pressure gauges, draught gauges, etc. VII. Before beginning a test...
Повний перегляд - Докладніше про цю книгу

A Manual of Steam-boilers : Their Design, Construction, and Operation: For ...

Robert Henry Thurston - 1890 - 704 стор.
...ashes, and water. 2. Tanks, or water-meters for measuring water. Watermeters, as a rule, should only be used as a check on other measurements. For accurate...temperatures of air, steam, feed-water, waste gases, etc. 4. Pressure-gauges, draught-gauges, etc. VII. Before beginning a test, the boiler and chimney should be...
Повний перегляд - Докладніше про цю книгу

A Handbook of Engine and Boiler Trials and of the Indicator and Prony Brake ...

Robert Henry Thurston - 1890 - 540 стор.
...ashes, and water. 2. Tanks, or water-meters for measuring water. Watermeters, as a rule, should only be used as a check on other measurements. For accurate...temperatures of air, steam, feed-water, waste gases, etc. 4. Pressure-gauges, draught-gauges, etc. VII. Before beginning a test, the boiler and chimney should be...
Повний перегляд - Докладніше про цю книгу

Modern Mechanism: Exhibiting the Latest Progress in Machines, Motors, and ...

Park Benjamin - 1892 - 962 стор.
...ashes, and water. 2. Tanks, or water-metres for measuring water. Water-metres as a rule should only be used as a check on other measurements. For accurate...temperatures of air, steam, feed-water, waste gases, etc. •I- Pressure-gauges, draft-gauges, etc. * The»- coals are selected because they are about the only...
Повний перегляд - Докладніше про цю книгу

Modern Mechanism: Exhibiting the Latest Progress in Machines, Motors, and ...

Park Benjamin - 1892 - 970 стор.
...ashes, and water. 3. Tanks, or water-metres for measuring water. Water-metres as a rule should only be used as a check on other measurements. For accurate...taking temperatures of air, steam, feed-water, waste gnses, etc. 4. Pressure-gauges, draft-gauges, etc. * These coals are selected because they are about...
Повний перегляд - Докладніше про цю книгу

Experimental Engineering and Manual for Testing: For Engineers and for ...

Rolla Clinton Carpenter - 1892 - 830 стор.
...ashes, and water. 2. Tanks, or water meters for measuring water. Water meters, as a rule, should only be used as a check on other measurements. For accurate...the water should be weighed or measured in a tank. (Appendices I., IV., VII., VIII.) 3. Thermometers and pyrometers for taking temperatures of air, steam,...
Повний перегляд - Докладніше про цю книгу




  1. Моя бібліотека
  2. Довідка
  3. Розширений пошук книг
  4. Завантажити ePub
  5. Завантажити файл PDF