... volt between its ends , or ten volts per thousand feet , which is by no means insignificant . Bars of this size or larger are often used in practice carrying correspondingly heavy currents ; hence it is not safe to ignore resistance ...
... volt between its ends , or ten volts per thousand feet , which is by no means insignificant . Bars of this size or larger are often used in practice carrying correspondingly heavy currents ; hence it is not safe to ignore resistance ...
Сторінка 17
... volts per lamp . 2. Series incandescent lighting . About 10 amperes and 10 to 30 volts per lamp ( about 3 candle- power per volt ) . 3. Series incandescent lighting ( " Municipal systems " ) . Three to 3.5 amperes and 20 to 50 volts per ...
... volts per lamp . 2. Series incandescent lighting . About 10 amperes and 10 to 30 volts per lamp ( about 3 candle- power per volt ) . 3. Series incandescent lighting ( " Municipal systems " ) . Three to 3.5 amperes and 20 to 50 volts per ...
Сторінка 18
... volts , two- and three - wire secondary circuits at about 50 , 100 , or 200 volts . 17. Very high tension systems with step - up and step - down transformers . Long distance transmission circuit 5,000 to 25,000 volts . Polyphase ...
... volts , two- and three - wire secondary circuits at about 50 , 100 , or 200 volts . 17. Very high tension systems with step - up and step - down transformers . Long distance transmission circuit 5,000 to 25,000 volts . Polyphase ...
Сторінка 19
... volts , it follows that the total pressure approximates 3,000 volts . The problem of designing or studying series circuits is not difficult , the path of the current being usually simple , and the current constant throughout the circuit ...
... volts , it follows that the total pressure approximates 3,000 volts . The problem of designing or studying series circuits is not difficult , the path of the current being usually simple , and the current constant throughout the circuit ...
Сторінка 20
... volts , and the same amount between the middle point and the brush . Similarly any two points on the circuit will have a difference of potential equal to fifty volts , multiplied by the number of lamps included between them . - Personal ...
... volts , and the same amount between the middle point and the brush . Similarly any two points on the circuit will have a difference of potential equal to fifty volts , multiplied by the number of lamps included between them . - Personal ...
Інші видання - Показати все
Electric Lighting: A Practical Exposition of the Art, for the Use of ... Francis Bacon Crocker Попередній перегляд недоступний - 2016 |
Загальні терміни та фрази
alternating current amperes apparatus arc lamps armature arrangement bulb bus bars cable candle-power capacity carbon cent circular mils conductors conduit connected constant current constant potential copper loss core cross-arm cross-section cut-out device diameter difference direct current distribution drop dynamo effect efficiency electric lighting electrical conductors employed energy equal fact feeders feeding-points filament flow frequency full load fuse globe ground heat hence incandescent lamps inch inclosed arc increase inductance insulation iron joint latter length less machines magnetic maximum mechanical metal meter method motor number of lamps ohms one-half open arc operation ordinary parallel phase pipe placed pole polyphase porcelain practically pressure primary produced reactance regulation represented in Fig resistance rheostat rotary rotary converters secondary circuit shown in Fig shunt side single-phase socket supplied switch temperature terminal three-phase three-wire system tion transformers tube two-phase two-wire two-wire circuit usually voltage volts wattmeter watts winding
Популярні уривки
Сторінка 460 - The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulations by the heat of the wires, but not from fear of igniting the insulation. The question of drop is not taken into consideration in the above tables.
Сторінка 11 - W, we find that the most economical area of conductor is that for which the annual cost of energy wasted is equal to the annual interest on that portion of the capital outlay which can be considered to be proportional to the weight of metal used. Professor George Forbes, in his Cantor Lecture, on " The Distribution of Electricity...
Сторінка 459 - Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they cannot come in contact with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause trouble on a circuit.