Electric Lighting: A Practical Exposition of the Art, for the Use of Engineers, Students, and Others Interested in the Installation Or Operation of Electrical Plants, Том 2D. Van Nostrand Company, 1901 |
З цієї книги
Результати 1-5 із 100
Сторінка 1
... ordinary English system of units can be employed to meas- ure the length and cross - section of wires or conductors . * The for- mer system , in spite of its many advantages , is rarely used for this purpose in America or in England ...
... ordinary English system of units can be employed to meas- ure the length and cross - section of wires or conductors . * The for- mer system , in spite of its many advantages , is rarely used for this purpose in America or in England ...
Сторінка 5
... ordinary screw micrometer . tance . A very simple and convenient rule to remember is the fact that 1,000 feet of No. 10 A. W. G. wire , which is practically one- tenth of an inch in diameter ( .1019 ) , has 1 ohm resistance at 20 ...
... ordinary screw micrometer . tance . A very simple and convenient rule to remember is the fact that 1,000 feet of No. 10 A. W. G. wire , which is practically one- tenth of an inch in diameter ( .1019 ) , has 1 ohm resistance at 20 ...
Сторінка 7
... ordinary form of Matthiessen's formula ( Equa . 3 ) , and gives slightly different results from those set forth in the table on page 8 , as already explained . The very simple expression , Rt = 9.6 ( 1.004 ) I d2 ( 6 ) gives values ...
... ordinary form of Matthiessen's formula ( Equa . 3 ) , and gives slightly different results from those set forth in the table on page 8 , as already explained . The very simple expression , Rt = 9.6 ( 1.004 ) I d2 ( 6 ) gives values ...
Сторінка 9
... ordinary form I ER into E = IR . = This is not only true of the whole cir- cuit , but also applies to any portion or branch of the circuit ; and ordinarily it is far simpler and more likely to avoid errors if each part of the circuit is ...
... ordinary form I ER into E = IR . = This is not only true of the whole cir- cuit , but also applies to any portion or branch of the circuit ; and ordinarily it is far simpler and more likely to avoid errors if each part of the circuit is ...
Сторінка 24
... ordinary types of machine for supplying a large number ( 50 to 200 ) of arc lamps in series . On the other hand , it is necessary to arrange the line in several loops instead of having one long cir- cuit . In Fig . 6 , for example ...
... ordinary types of machine for supplying a large number ( 50 to 200 ) of arc lamps in series . On the other hand , it is necessary to arrange the line in several loops instead of having one long cir- cuit . In Fig . 6 , for example ...
Інші видання - Показати все
Electric Lighting: A Practical Exposition of the Art, for the Use of ... Francis Bacon Crocker Попередній перегляд недоступний - 2016 |
Загальні терміни та фрази
alternating current amperes apparatus arc lamps armature arrangement bulb bus bars cable candle-power capacity carbon cent circular mils conductors conduit connected constant current constant potential copper loss core cross-arm cross-section cut-out device diameter difference direct current distribution drop dynamo effect efficiency electric lighting electrical conductors employed energy equal fact feeders feeding-points filament flow frequency full load fuse globe ground heat hence incandescent lamps inch inclosed arc increase inductance insulation iron joint latter length less machines magnetic maximum mechanical metal meter method motor number of lamps ohms one-half open arc operation ordinary parallel phase pipe placed pole polyphase porcelain practically pressure primary produced reactance regulation represented in Fig resistance rheostat rotary rotary converters secondary circuit shown in Fig shunt side single-phase socket supplied switch temperature terminal three-phase three-wire system tion transformers tube two-phase two-wire two-wire circuit usually voltage volts wattmeter watts winding
Популярні уривки
Сторінка 460 - The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulations by the heat of the wires, but not from fear of igniting the insulation. The question of drop is not taken into consideration in the above tables.
Сторінка 11 - W, we find that the most economical area of conductor is that for which the annual cost of energy wasted is equal to the annual interest on that portion of the capital outlay which can be considered to be proportional to the weight of metal used. Professor George Forbes, in his Cantor Lecture, on " The Distribution of Electricity...
Сторінка 459 - Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they cannot come in contact with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause trouble on a circuit.