... lamps are treated in considerable detail , since they are important features in electric lighting , and have not been very fully treated in other publications . Interior wiring , incandescent and other forms of lamps , and finally ...
... lamps are treated in considerable detail , since they are important features in electric lighting , and have not been very fully treated in other publications . Interior wiring , incandescent and other forms of lamps , and finally ...
Сторінка
... lamps . Mr. John W. Howell , of the General Electric Lamp Works , very kindly read over the proof of the chapter on incandescent lamps , in which subject no one has had greater and more successful experience . Mr. C. S. Aylmer - Small ...
... lamps . Mr. John W. Howell , of the General Electric Lamp Works , very kindly read over the proof of the chapter on incandescent lamps , in which subject no one has had greater and more successful experience . Mr. C. S. Aylmer - Small ...
Сторінка
... LAMPS . 329 CHAPTER XVI . INTERIOR WIRING 371 CHAPTER XVII . INCANDESCENT LAMPS 395 CHAPTER XVIII . LAMPS NOT EMPLOYING CARBON 427 ELECTRIC METERS CHAPTER XIX . 432 APPENDIX I. NATIONAL ELECTRIC CODE 451 APPENDIX II . REPORT OF THE ...
... LAMPS . 329 CHAPTER XVI . INTERIOR WIRING 371 CHAPTER XVII . INCANDESCENT LAMPS 395 CHAPTER XVIII . LAMPS NOT EMPLOYING CARBON 427 ELECTRIC METERS CHAPTER XIX . 432 APPENDIX I. NATIONAL ELECTRIC CODE 451 APPENDIX II . REPORT OF THE ...
Сторінка 17
... lamp ( 1 volt ) per candle- power ) . 4. Series - parallel incandescent lighting . Similar to No. 2 , but single lamps replaced by groups in parallel . 5. Direct current converter systems for incandescent or arc lighting . Motor ...
... lamp ( 1 volt ) per candle- power ) . 4. Series - parallel incandescent lighting . Similar to No. 2 , but single lamps replaced by groups in parallel . 5. Direct current converter systems for incandescent or arc lighting . Motor ...
Сторінка 18
... incandescent and arc lighting without transformers . This corresponds to No. 11. Other alternating current systems similar to Nos . 12 , 13 , and 14 have not been introduced . 16. High - tension incandescent and arc lighting with ...
... incandescent and arc lighting without transformers . This corresponds to No. 11. Other alternating current systems similar to Nos . 12 , 13 , and 14 have not been introduced . 16. High - tension incandescent and arc lighting with ...
Інші видання - Показати все
Electric Lighting: A Practical Exposition of the Art, for the Use of ... Francis Bacon Crocker Попередній перегляд недоступний - 2016 |
Загальні терміни та фрази
alternating current amperes apparatus arc lamps armature arrangement bulb bus bars cable candle-power capacity carbon cent circular mils conductors conduit connected constant current constant potential copper loss core cross-arm cross-section cut-out device diameter difference direct current distribution drop dynamo effect efficiency electric lighting electrical conductors employed energy equal fact feeders feeding-points filament flow frequency full load fuse globe ground heat hence incandescent lamps inch inclosed arc increase inductance insulation iron joint latter length less machines magnetic maximum mechanical metal meter method motor number of lamps ohms one-half open arc operation ordinary parallel phase pipe placed pole polyphase porcelain practically pressure primary produced reactance regulation represented in Fig resistance rheostat rotary rotary converters secondary circuit shown in Fig shunt side single-phase socket supplied switch temperature terminal three-phase three-wire system tion transformers tube two-phase two-wire two-wire circuit usually voltage volts wattmeter watts winding
Популярні уривки
Сторінка 460 - The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulations by the heat of the wires, but not from fear of igniting the insulation. The question of drop is not taken into consideration in the above tables.
Сторінка 11 - W, we find that the most economical area of conductor is that for which the annual cost of energy wasted is equal to the annual interest on that portion of the capital outlay which can be considered to be proportional to the weight of metal used. Professor George Forbes, in his Cantor Lecture, on " The Distribution of Electricity...
Сторінка 459 - Must be so placed in wet places that an air space will be left between conductors and pipes in crossing, and the former must be run in such a way that they cannot come in contact with the pipe accidentally. Wires should be run over, rather than under, pipes upon which moisture is likely to gather or which, by leaking, might cause trouble on a circuit.