Сторінка 3 - Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors.
Сторінка 210 - Main or Feeder run exposed. Branch Circuit run concealed under Floor. Branch Circuit run concealed under Floor above. Branch Circuit run exposed. -»- - Pole Line.
Сторінка 210 - Push button outlet. Numeral indicates number of pushes. Annunciator. Numeral indicates number of points. Speaking tube. Watchman clock outlet. Watchman station outlet. Master time clock outlet. Secondary time clock outlet. Door opener. Special outlet for signal systems, as described in specifications.
Сторінка 210 - Battery outlet. Circuit for clock, telephone, bell or other service, run . under floor, concealed.
Сторінка 55 - C', C", etc., of the ^ 19< cells A, A', A", etc., are connected, as are the zinc elements B, B', B' , etc. The copper terminal and the zinc terminal of cell A are connected to the line. With this arrangement the effective EMF is that of one cell, but the current giving capacity is equal to that of one cell multiplied by the number of cells.
Сторінка 238 - The first phonograph; improving the telegraph so that six messages can be sent over the same wire at the same time...
Сторінка 141 - No. 51 a, and the outer surface must be thoroughly slicked down. This wire is for use outdoors, where moisture is certain and where fireproof qualities are not necessary.
Сторінка 47 - ... inches. In no case shall signaling wires be run in the same tube with electric light or power wires. p. Transformers or other devices for supplying current to signaling systems from light, heat or power circuits must be of a design expressly approved for this purpose. The primary wiring must be installed in accordance with the rules for " Class C," and the secondary wiring in accordance with
Сторінка 3 - ... in contact with electric light or power wires. 6. Provided with petticoat insulators of glass or porcelain. Porcelain knobs and rubber hooks are prohibited. 7. So spliced or joined as to be both mechanically and electrically secure without solder. They must then be soldered to insure preservation, and covered with an insulation equal to that on the conductors. The following formula for soldering fluid is approved: Saturated solution of zinc . . 5 parts. Alcohol . . . . . . 4 parts. Glycerine...