New Catechism of Electricity: A Practical TreatiseT. Audel, 1896 - 541 стор. |
З цієї книги
Результати 1-5 із 46
Сторінка 181
... switches controlling the external circuits should be opened , as the machine excites best when this is the case ; and when the machine is provided with a rheostat or hand regulator and resistance coils , these latter should all be cut ...
... switches controlling the external circuits should be opened , as the machine excites best when this is the case ; and when the machine is provided with a rheostat or hand regulator and resistance coils , these latter should all be cut ...
Сторінка 190
... switch should be opened . This reduces the sparking at the switch contacts , and prevents the engine racing . CARE AND MANAGEMENT OF THE DYNAMO . When the voltmeter 190 NEW CATECHISM OF ELECTRICITY .
... switch should be opened . This reduces the sparking at the switch contacts , and prevents the engine racing . CARE AND MANAGEMENT OF THE DYNAMO . When the voltmeter 190 NEW CATECHISM OF ELECTRICITY .
Сторінка 198
... switches , so arranged that either the resistance of the field magnet circuit may be varied , by inserting or removing resistance in series with the latter , or one or more of the exciting coils may be cut into or out of circuit , or ...
... switches , so arranged that either the resistance of the field magnet circuit may be varied , by inserting or removing resistance in series with the latter , or one or more of the exciting coils may be cut into or out of circuit , or ...
Сторінка 199
... switch or regu- lator , shown at the bottom of the figure . This is composed of twelve contacts , each contact being electrically connected to the bottom junction of a spiral coil . By altering the position of the lever of the regulator ...
... switch or regu- lator , shown at the bottom of the figure . This is composed of twelve contacts , each contact being electrically connected to the bottom junction of a spiral coil . By altering the position of the lever of the regulator ...
Сторінка 214
... switches S1 S2 , and the double pole fuses F , F. Ammeters , A1 A2 , are inserted in the main circuit of each machine , and serve to indicate the amount of current generated by each . An automatic switch or cutout , AC , AC2 , is also ...
... switches S1 S2 , and the double pole fuses F , F. Ammeters , A1 A2 , are inserted in the main circuit of each machine , and serve to indicate the amount of current generated by each . An automatic switch or cutout , AC , AC2 , is also ...
Інші видання - Показати все
Загальні терміни та фрази
adjusted alternating current ammeter amperes apparatus arc light armature arranged bars battery bearings belt BOARD FIRE UNDERWRITERS Boiler brushes carbon cause cell commutator conducting conductors connected construction copper core COUPLING OF DYNAMOS current flowing current of electricity cut-out direct current direction disconnection drum electric current electric energy ELECTRIC LIGHTING ELECTRIC POWER TRANSMISSION ELECTRICAL RESISTANCE electro-magnet electromotive-force excessive exciting fault field coils field magnet fuse galvanometer hand regulator heat incandescent inch insulation iron lamps liable lines of force load machine magnetic field metal method motion motor NATIONAL BOARD FIRE needle parallel passing pipes placed plate points pole pieces position practical pressure produced pulley QUES resistance rheostat ring rotating RULES AND REQUIREMENTS screw segments shaft short circuit shown in Fig solder sparking speed surface switch telegraph telephone terminals tion tube vibration voltage voltmeter volts winding WIRING RULES wound zinc
Популярні уривки
Сторінка 396 - Must be so suspended that the entire weight of the socket and lamp will be borne by knots under the bushing in the socket, and above the point where the cord comes through the ceiling block or rosette, in order that the strain may be taken from the joints and binding screws.
Сторінка iv - All our industries would cease, were it not for that information which men begin to acquire as they best may after their education is said to be finished.
Сторінка iv - The vital knowledge— that by which we have grown as a nation to what we are, and which now underlies our whole existence, is a knowledge that has got itself taught in nooks and corners; while the ordained agencies for teaching have been mumbling little else but dead formulas.
Сторінка 386 - Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors.
Сторінка 523 - This manoeuvre should likewise be repeated at least sixteen times per minute. This serves the double purpose of freeing the throat so as to permit air to enter the lungs, and also, by exciting a reflex irritation from forcible contact of the under part of the tongue against the lower teeth, frequently stimulates an involuntary effort at respiration.
Сторінка 404 - Special attention is called to the fact that switchboards should not be built down to the floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four inches between the ceiling and the board, in order to prevent fire from communicating from the switchboard to the floor or ceiling and also to prevent the forming of a partially concealed space very...
Сторінка 523 - ... and hold them there for two or three seconds only. (This is to expand the chest and favor the entrance of air into the lungs.) Then carry the arms down to the sides and front of the chest, firmly compressing the chest walls, and expel the air from the lungs. Repeat this maneuver at least sixteen times per minute.
Сторінка 521 - Rule (1) — Remove the body at once from the circuit by breaking contact with the conductors. This may be accomplished by using a dry stick of wood, which is a nonconductor, to roll the body over to one side, or to brush aside a wire, if that is conveying the current. When a stick is not at hand, any dry piece of clothing may be utilized to protect the hand in seizing the body of the victim, unless rubber gloves are convenient. If the body is in contact with the earth, the...
Сторінка 389 - Must not be of such material or construction that the insulation of the conductdr will ultimately be injured or destroyed by the elements of the composition. c. Must be first installed as a complete conduit system, without conductors, strings, or anything for the purpose of drawing in the conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been, as far as possible, completed. d. Must not be so placed...
Сторінка 401 - All cut-outs and safety devices in place in the above. Where lamp sockets, receptacles and electroliers, etc., are connected, one-half of the above will be required.