New Catechism of Electricity: A Practical Treatise

Передня обкладинка
T. Audel, 1896 - 541 стор.
 

Інші видання - Показати все

Загальні терміни та фрази

Популярні уривки

Сторінка 396 - Must be so suspended that the entire weight of the socket and lamp will be borne by knots under the bushing in the socket, and above the point where the cord comes through the ceiling block or rosette, in order that the strain may be taken from the joints and binding screws.
Сторінка iv - All our industries would cease, were it not for that information which men begin to acquire as they best may after their education is said to be finished.
Сторінка iv - The vital knowledge— that by which we have grown as a nation to what we are, and which now underlies our whole existence, is a knowledge that has got itself taught in nooks and corners; while the ordained agencies for teaching have been mumbling little else but dead formulas.
Сторінка 386 - Must be so spliced or joined as to be both mechanically and electrically secure without solder. The joints must then be soldered, to insure preservation, and covered with an insulation equal to that on the conductors.
Сторінка 523 - This manoeuvre should likewise be repeated at least sixteen times per minute. This serves the double purpose of freeing the throat so as to permit air to enter the lungs, and also, by exciting a reflex irritation from forcible contact of the under part of the tongue against the lower teeth, frequently stimulates an involuntary effort at respiration.
Сторінка 404 - Special attention is called to the fact that switchboards should not be built down to the floor, nor up to the ceiling, but a space of at least ten or twelve inches should be left between the floor and the board, and from eighteen to twenty-four inches between the ceiling and the board, in order to prevent fire from communicating from the switchboard to the floor or ceiling and also to prevent the forming of a partially concealed space very...
Сторінка 523 - ... and hold them there for two or three seconds only. (This is to expand the chest and favor the entrance of air into the lungs.) Then carry the arms down to the sides and front of the chest, firmly compressing the chest walls, and expel the air from the lungs. Repeat this maneuver at least sixteen times per minute.
Сторінка 521 - Rule (1) — Remove the body at once from the circuit by breaking contact with the conductors. This may be accomplished by using a dry stick of wood, which is a nonconductor, to roll the body over to one side, or to brush aside a wire, if that is conveying the current. When a stick is not at hand, any dry piece of clothing may be utilized to protect the hand in seizing the body of the victim, unless rubber gloves are convenient. If the body is in contact with the earth, the...
Сторінка 389 - Must not be of such material or construction that the insulation of the conductdr will ultimately be injured or destroyed by the elements of the composition. c. Must be first installed as a complete conduit system, without conductors, strings, or anything for the purpose of drawing in the conductors, and the conductors then to be pushed or fished in. The conductors must not be placed in position until all mechanical work on the building has been, as far as possible, completed. d. Must not be so placed...
Сторінка 401 - All cut-outs and safety devices in place in the above. Where lamp sockets, receptacles and electroliers, etc., are connected, one-half of the above will be required.