... tests . Fig . 11 shows a round joint and a branch joint set up , ready for wiping , with soil applied . Another method of preventing the adhesion of solder outside the joint , is by means of paper pasted onto the pipe . The paper covers ...
... tests . Fig . 11 shows a round joint and a branch joint set up , ready for wiping , with soil applied . Another method of preventing the adhesion of solder outside the joint , is by means of paper pasted onto the pipe . The paper covers ...
Сторінка 43
... testing it , is to thrust into the molten solder a shaving or a piece of paper rolled up . If the shaving or paper takes fire , the metal is too hot , but if the material chars quickly , the solder is right to use . Some expe- rienced ...
... testing it , is to thrust into the molten solder a shaving or a piece of paper rolled up . If the shaving or paper takes fire , the metal is too hot , but if the material chars quickly , the solder is right to use . Some expe- rienced ...
Сторінка 69
... Testing of Traps . interest , and tend to show how closely some of them are approxi- mating in their operation the result which is desired . The general method of testing traps is illustrated in Fig . 31 . A tank holding about 200 ...
... Testing of Traps . interest , and tend to show how closely some of them are approxi- mating in their operation the result which is desired . The general method of testing traps is illustrated in Fig . 31 . A tank holding about 200 ...
Сторінка 70
... tested is attached , as shown . A quick - opening valve having a full water - way should control the flush , by ... tests , within the first minute , from 1 to 2 inches of their seal , and often a greater amount . However , in many cases ...
... tested is attached , as shown . A quick - opening valve having a full water - way should control the flush , by ... tests , within the first minute , from 1 to 2 inches of their seal , and often a greater amount . However , in many cases ...
Сторінка 71
... tested . Therefore , the perfect trap should be so constructed as to overcome this danger . The term " trap seal " has been used several times , and it is a matter of importance . Fig . 32 is given as a means of defining it . Under ...
... tested . Therefore , the perfect trap should be so constructed as to overcome this danger . The term " trap seal " has been used several times , and it is a matter of importance . Fig . 32 is given as a means of defining it . Under ...
Зміст
17 | |
35 | |
53 | |
63 | |
64 | |
73 | |
81 | |
95 | |
190 | |
201 | |
208 | |
216 | |
246 | |
265 | |
289 | |
311 | |
101 | |
108 | |
119 | |
141 | |
148 | |
154 | |
323 | |
339 | |
364 | |
383 | |
Інші видання - Показати все
Standard Practical Plumbing: An Exhaustive Treatise On All Branches of ... Robert Macy Starbuck Попередній перегляд недоступний - 2022 |
Загальні терміни та фрази
action ball cock bath room branch brass calked capillary action carburetor cellar drain chamber chapter circulation pipe cleanout close coil Concrete construction continuous vent device drainage system drawings drum trap engine ferrule filter filtered water fitting fixture floor flow pipe flush fresh-air inlet Gear heating horizontal hot water house drain house sewer inches installed lathes Lavatory lead bend lead pipe located Main Stack main trap main vent matter mechanical method O'CONOR SLOANE oakum opening operation Pipt plumber plumbing system practical pressure Price principle rain leaders range boiler range connection roof seen in Fig sewage shown in Fig shows sink siphon siphonage smoke test soil pipe solder steam stoppage surface tank Testing Plug tion trap seal trap vent trouble vacuum valve vent connection ventilation Vert waste pipe water front water supply water-closet wiped joint wiping cloths wrought iron