Standard Practical Plumbing: An Exhaustive Treatise on All Branches of Plumbing Construction Including Drainage and Venting, Ventilation, Hot and Cold Water Supply and Circulation ...Norman W. Henley Publishing Company, 1910 - 396 стор. |
З цієї книги
Результати 1-5 із 100
Сторінка 14
... BOILERS - THEORY OF CIRCULATION 289 CHAPTER XXIV CIRCULATING PIPES 311 CHAPTER XXV PROBLEMS IN RANGE BOILER WORK • CHAPTER XXVI 323 HOT - WATER SUPPLY FOR OFFICE AND APARTMENT BUILDINGS , ETC. 339 • CHAPTER XXVII THE WATER LIFT AND ITS ...
... BOILERS - THEORY OF CIRCULATION 289 CHAPTER XXIV CIRCULATING PIPES 311 CHAPTER XXV PROBLEMS IN RANGE BOILER WORK • CHAPTER XXVI 323 HOT - WATER SUPPLY FOR OFFICE AND APARTMENT BUILDINGS , ETC. 339 • CHAPTER XXVII THE WATER LIFT AND ITS ...
Сторінка 265
... boilers could be used only four or five years before being made entirely unfit for use , the pipes becoming almost completely filled and the boiler rusted through . On the other hand , he has seen galvanized supply piping taken out that ...
... boilers could be used only four or five years before being made entirely unfit for use , the pipes becoming almost completely filled and the boiler rusted through . On the other hand , he has seen galvanized supply piping taken out that ...
Сторінка 270
... bending the pipe instead of using elbows and offsets . When a header is used for the hot - water pipes , the hot - water pipe from the boiler is carried direct to the keyboard , and. FIG . 253. Keyboard . 270 STANDARD PRACTICAL PLUMBING.
... bending the pipe instead of using elbows and offsets . When a header is used for the hot - water pipes , the hot - water pipe from the boiler is carried direct to the keyboard , and. FIG . 253. Keyboard . 270 STANDARD PRACTICAL PLUMBING.
Сторінка 271
... boiler is carried direct to the keyboard , and from that point delivered to the several lines . When a circulation or return header is used , it should be connected into the return opening of the range or heater . In order to derive ...
... boiler is carried direct to the keyboard , and from that point delivered to the several lines . When a circulation or return header is used , it should be connected into the return opening of the range or heater . In order to derive ...
Сторінка 272
... boiler and all fixtures . In the use of the present tank , however , it is designed chiefly to supply the range boiler , the cold - water supply to fixtures being under street pressure . In the tank system as at present used , then ...
... boiler and all fixtures . In the use of the present tank , however , it is designed chiefly to supply the range boiler , the cold - water supply to fixtures being under street pressure . In the tank system as at present used , then ...
Зміст
17 | |
35 | |
53 | |
63 | |
64 | |
73 | |
81 | |
95 | |
190 | |
201 | |
208 | |
216 | |
246 | |
265 | |
289 | |
311 | |
101 | |
108 | |
119 | |
141 | |
148 | |
154 | |
323 | |
339 | |
364 | |
383 | |
Інші видання - Показати все
Standard Practical Plumbing: An Exhaustive Treatise On All Branches of ... Robert Macy Starbuck Попередній перегляд недоступний - 2022 |
Загальні терміни та фрази
action ball cock bath room branch brass calked capillary action carburetor cellar drain chamber chapter circulation pipe cleanout close coil Concrete construction continuous vent device drainage system drawings drum trap engine ferrule filter filtered water fitting fixture floor flow pipe flush fresh-air inlet Gear heating horizontal hot water house drain house sewer inches installed lathes Lavatory lead bend lead pipe located Main Stack main trap main vent matter mechanical method O'CONOR SLOANE oakum opening operation Pipt plumber plumbing system practical pressure Price principle rain leaders range boiler range connection roof seen in Fig sewage shown in Fig shows sink siphon siphonage smoke test soil pipe solder steam stoppage surface tank Testing Plug tion trap seal trap vent trouble vacuum valve vent connection ventilation Vert waste pipe water front water supply water-closet wiped joint wiping cloths wrought iron