vision is made for such flues and ducts when the building is first planned, the additional expense will be very slight indeed, and not to be considered when the advantages to be gained are taken into account. There is a great variety of methods in which the ventilation system may be installed. Fig. 170, for instance, shows a

FIG. 170.-Local Ventilation by Means of Raised Rear Vent Water-Closets.

[blocks in formation]

FIG. 171.-End View of Local Vent System for Double Line of Water-Closets.

ד

[graphic]

common method of running a galvanized iron duct back of the partition against which the water-closets stand, thus concealing the work entirely. In Fig. 171 is shown another common and excellent method applicable to a single or double line of waterclosets.

The vent chamber runs the entire length of the line of fixtures, and into it the raised rear vent of each fixture is connected. From the top of the vent chamber a pipe is carried to the flue which is to be used for ventilation. An excellent feature of Fig. 171 is that the vent chamber may be used also as a utility chamber. Its convenience in this respect may be seen from the fact that the supply pipes, flushing valves, and the back venting for the double

FIG. 172.-Local Ventilation for Comfort Station or Similar Toilet Building.

line of fixtures may be located in this chamber, entirely concealed from view. When so used, a door should be cut into the chamber, to allow entrance for repairs. In Fig. 172, which represents such a toilet room as might be found in a comfort station, a method slightly different is shown. In this instance, there being no flue built into the walls, a galvanized iron flue is carried through the roof, and into it the vent pipes from the two vent chambers are connected.

A ventilator at the top of the flue will add greatly to the effectiveness of the system. It used to be considered that unless local vent pipes could be connected to a heated flue they could not be effective.

[ocr errors][ocr errors][subsumed][subsumed][subsumed][subsumed]

This is no longer considered true, although if they can be so connected the results will be so much the better. Many toilet rooms are now provided with local ventilation in which it is impossible to use a heated flue, but this does not prevent excellent results being obtained from a flue or duct carried through the roof as in Fig. 172. In this case, however, as much assistance as possible should be given by the use of a ventilator, an electric fan placed in the flue, or a gas jet so placed. Local ventilation

[graphic]

FIG. 173.-Local Ventilation for Toilet Rooms, Including Ventilation of Urinals.

may be provided in old buildings as well as in new ones, the only difference being that in old buildings the piping must often be exposed to view. However, when properly installed, such ducts are by no means unsightly. The writer recalls an old-time building in which local ventilation has recently been installed with results entirely satisfactory. The toilet rooms in this building are without natural light and without communication with the outer air, conditions under which results are generally most difficult to obtain. In this instance the pipes had to be installed exposed to

[ocr errors]

view. There was no heated flue at hand, and the ducts were consequently run through the roof with a ventilator at the outer end. Such excellent results as are obtained under these poor conditions speak well for local ventilation and for water-closets with raised rear vents.

As previously stated, local ventilation may be applied with splendid results to urinals as well as to water-closets. A system of local ventilation in which urinal ventilation is provided is shown in Fig. 173. This method of ventilation has been in use for some little time and is worthy of far greater use than it has yet obtained. Both architects and plumbers would do well to talk it and recommend its use more generally.

CHAPTER XVII

MODERN IMPROVED PLUMBING CONNECTIONS

WITHIN a comparatively short time, a large number of especially efficient waste and vent fittings have appeared, which have great merit and have done much toward simplifying and improving waste and vent connections. In these days when the tendency

is toward complication, anything which will simplify the plumbing system is to be encouraged.

The author, personally, is inclined to date these improvements

[blocks in formation]

FIG. 174.-A Modern Vented Waste Fitting.

from the introduction of continuous venting, believing this system to be the indirect cause of many of these improvements. The fittings referred to present three most excellent features-they make it possible to gain a separate entrance into the drainage