" They should be stamped with about 80 per cent. of the maximum current which they can carry indefinitely, thus allowing about 25 per cent. overload before the fuse melts. With naked open fuses, of ordinary shapes and with not over 500 amperes... "
Cyclopedia of Engineering: A General Reference Work on Steam Boilers and ... - Сторінка 95
редактори - 1915
Повний перегляд - Докладніше про цю книгу

Electrical Catechism: An Introductory Treatise on Electricity and Its Uses

George Defrees Shepardson - 1901 - 434 стор.
...the underwriters require that each fuse be stamped with about 80 per cent of the maximum current it can carry indefinitely, thus allowing about 25 per cent overload before the fuse melts. 429. Does a fuse wire always melt with the same current? The fusing current is liable to vary 50 or...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power: As Adopted by the Fire ...

Harry Cooke Cushing - 1902 - 204 стор.
...provided for holding the fuse. They should be stamped with about 80 per cent, of the maximum current they can carry indefinitely, thus allowing about 25 per cent, overload before the fuse melts. With naked open fuses, of ordinary shapes, and not over 500 amperes capacity, the Maximum current which...
Повний перегляд - Докладніше про цю книгу

International Library of Technology: A Series of Textbooks for ..., Том 13

1902 - 738 стор.
...with the fusible part of the strip. b. Must be stamped with about 80 per cent. of the maximum current they can carry indefinitely, thus allowing about 25 per cent. overload before fuse melts. With naked, open fuses of ordinary shapes and not over 500 amperes capacity, the maximum...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Applied Electricity: Current measurements; Wiring; Telegraph

1905 - 484 стор.
...provided for holding the fuse. Fuses should be stamped with about 80 per cent of the maximum current they can carry indefinitely, thus allowing about 25 per cent overload before the fuse melts. With naked open fuses of ordinary shapes and not over 500 amperes capacity, the maximum current which...
Повний перегляд - Докладніше про цю книгу

Modern Engineering Practice: A Reference Library..., Том 1

American School (Chicago, Ill.) - 1906 - 528 стор.
...provided for holding the fuse. Fuses should be stamped with about 80 per cent of the maximum current they can carry indefinitely, thus allowing about 25 per cent overload before the fuse melts. With naked open fuses of ordinary shapes and not over 500 amperes capacity, the maximum current which...
Повний перегляд - Докладніше про цю книгу

Electric Light Wiring

Charles Edwin Knox - 1907 - 242 стор.
...ELECTRIC LIGHT WIRING DATA ON DIMENSIONS OF COPPER FUSES b. RATING. — Must be stamped with about 80 per cent of the maximum current which they can carry...about 25 per cent overload before the fuse melts. With naked open fuses, of ordinary shapes and with not over 500 amperes capacity, the minimum current...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Architecture, Carpentry and Building: A General Reference Work...

American School (Lansing, Ill.) - 1907 - 438 стор.
...provided for holding the fuse. Fuses should be stamped with about 80 per cent of the maximum current they can carry indefinitely, thus allowing about 25 per cent overload before the fuse melts. With naked open fuses of ordinary shapes and not over 500 amperes capacity, the maximum current which...
Повний перегляд - Докладніше про цю книгу

Journal, Том 41

1908 - 1016 стор.
...Electric Code (1905) as regards rating are as follows : — Fuses. — Must be stamped with about 80 per cent, of the maximum current which they can carry...about 25 per cent, overload before the fuse melts. NOTE : With naked open fuses of ordinary shapes and with not over 500 amperes capacity the minimum...
Повний перегляд - Докладніше про цю книгу

Proceedings of the Institution of Electrical Engineers, Том 41

Institution of Electrical Engineers - 1908 - 958 стор.
...Code (1905) as regards rating are as follows : — Open-type Fuses. — Must be stamped with about 80 per cent, of the maximum current which they can carry...about 25 per cent. overload before the fuse melts. NOTE : With naked open fuses of ordinary shapes and with not over 500 amperes capacity the minimum...
Повний перегляд - Докладніше про цю книгу

Modern Electrical Construction: A Reliable, Practical Guide for the Beginner ...

Henry Charles Horstmann, Victor Hugo Tousley - 1908 - 352 стор.
...clamps, or other devices provided for holding the fuse. b. Rating. — Must be stamped with about 80 per cent of the maximum current which they can carry...about 25 per cent overload before the fuse melts. With naked open fuses, of ordinary shapes and with not over 500 amperes capacity, the minimum current...