" ... systems must not at Central Stations be smaller than the neutral wire and not smaller than No. 6 B. & S. "
Practical Operation of Arc Lamps - Сторінка 50
автори: National Carbon Company, Inc - 1911 - 75 стор.
Повний перегляд - Докладніше про цю книгу

Electric Lighting: A Practical Exposition of the Art, for the Use of ..., Том 2

Francis Bacon Crocker - 1901 - 528 стор.
...in AC systems must never be less than No. 6 B. & S., and must always have equal carrying capacity to the secondary lead of the transformer, or the combined leads where transformers are banked. e. The ground wire must be kept outside of buildings, but may be directly attached to the building...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ...

Horatio Alvah Foster - 1901 - 1018 стор.
...in AC systems must never be less than No. G B. & S., and must always have equal carrying capacity to the secondary lead of the transformer, or the combined leads where transformers are banked. e. The ground wire must be kept outside of buildings, but may be directly attached to the building...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power: As Adopted by the Fire ...

Harry Cooke Cushing - 1902 - 204 стор.
...systems should never be less than No. 6 B. & S., and should always have equal carrying capacity to the secondary lead of the transformer, or the combined leads where transformers are banked. These wires should be kept outside of buildings, but may be directly attached to the building...
Повний перегляд - Докладніше про цю книгу

Practical Lessons in Electricity. Elements of Electricity. The Electric Current

American School (Lansing, Ill.) - 1903 - 320 стор.
...ground wire should never be less than Xo. 6 B. & S., and should always have equal carrying capacity to the secondary lead of the transformer, or the combined leads where transformers are banked. These wires should be kept outside of buildings, but may be directly attached to the building...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Applied Electricity: Current measurements; Wiring; Telegraph

1905 - 484 стор.
...ground wire should never be less than No. 6 B. & S., and should always have equal carrying capacity to the secondary lead of the transformer, or the combined leads where transformers arc banked. These wires should be kept outside of buildings, but may be directly attached to the building...
Повний перегляд - Докладніше про цю книгу

Modern Engineering Practice: A Reference Library..., Том 1

American School (Chicago, Ill.) - 1906 - 528 стор.
...ground wire should never be less than Xo. 6 B. & S., and should always have equal carrying capacity to the secondary lead of the transformer, or the combined leads where transformers are banked. These wires should be kept outside of buildings, but may be directly attached to the building...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Engineering: A Manual of Steam Boilers, Steam Pumps ..., Том 5

1906 - 590 стор.
...ground wire should never be less than Xo. 6 B. & S., and should always have equal carrying capacity to the secondary lead of the transformer, or the combined leads where transformers are banked. These wires should be kept outside of buildings, but may be directly attached to the building...
Повний перегляд - Докладніше про цю книгу

Cyclopedia of Architecture, Carpentry and Building: A General Reference Work...

American School (Lansing, Ill.) - 1907 - 438 стор.
...ground wire should never be less than Xo. 6 B. & S., and should always have equal carrying capacity to the secondary lead of the transformer, or the combined leads where transformers are banked. These wires should be kept outside of buildings, but may be directly attached to the building...
Повний перегляд - Докладніше про цю книгу

Sessional Papers - Legislature of the Province of Ontario, Том 11

Ontario. Legislative Assembly - 1912 - 728 стор.
...elsewhere. The round wire in alternating current systems must never be less than No. 4 B. & S. gauge. On three-phase systems, the ground wire must have a carrying capacity equal to that of any one of the three mains. (e) Except in central and transformer sub-stations, ground wires...
Повний перегляд - Докладніше про цю книгу

The Electrical Code ...: Comprising the Rules and Regulations for the ...

1913 - 242 стор.
...elsewhere. The ground wire in alternating-current systems must never be less than No. 6 B. & S. gage. On three-phase systems the ground wire must have a carrying capacity equal to that of any one of the three mains. e. The ground wire must, except for Central Stations and transformer...
Повний перегляд - Докладніше про цю книгу