...The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulations by the heat of the wires, but not from...used, except as allowed under Rules 24 u and 40 c. 17. SWITCHES, CUT-OUTS, CIRCUIT BKEAKERS, ETC. — (For construction rules, see Nos. 43, 44, and 45.)... | |
| Horatio Alvah Foster - 1901 - 1018 стор.
...The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulations by the heat of the wires, but not from...than fourteen is to be used, except as allowed under Kules 24£ and 45 6. 17. Snitches. < ii i. MI t- Circuit-Breakers, etc.— (For construction rules,... | |
| George Defrees Shepardson - 1901 - 430 стор.
...The lower limit is specified for rubber-covered wires, to prevent gradual deterioration of the high insulations by the heat of the wires, but not from...but no smaller than fourteen is to be used, except in pendants and in fixtures. The choice between weatherproof and rubber-covered wires depends upon... | |
| Francis Bacon Crocker - 1901 - 514 стор.
...rubber-covered wires to prevent gradual deterioration of the high insulations by the heat of the wires, but npt from fear of igniting the insulation. The question...fourteen Is to be used, except as allowed under Rules 24 ' and 45 .-• 17. Switches, Cutouts, Circuit-Breakers, etc. (For construction rules, see IVos. 51,... | |
| Francis Bacon Crocker - 1901 - 528 стор.
...The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulations by the heat of the wires, but not from...eighteen wire is given, but no smaller than fourteen b to be used, except as allowed under Rules 24 t and 45 b. 17. Switches, Cutouts, Circuit-Breakers,... | |
| George Defrees Shepardson - 1901 - 434 стор.
...rubber-covered wires, to prevent decentering of the wire and deterioration of the insulation by the heat but not from fear of igniting the insulation. The...but no smaller than fourteen is to be used, except in pendants and in fixtures. The choice between weatherproof and rubber-covered wires depends upon... | |
| Wisconsin - 1901 - 884 стор.
...The lower limit is specified for rubber covered wires to prevent gradual deterioration of the high insulations by the heat of the wires, but not from...the insulation. The question of drop is not taken in consideration in the above tables. Penalty for violations. SECTION 4. Any violation of the provisions... | |
| Wisconsin - 1901 - 900 стор.
...The lower limit is specified for rubber covered wires to prevent gradual deterioration of the high insulations by the heat of the wires, but not from...the insulation. The question of drop is not taken in consideration in the above tables. Penalty for violations. SECTION 4. Any violation of the provisions... | |
| George Velten Steeb - 1902 - 230 стор.
...The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulations by the heat of the wires, but not from...above tables. The carrying capacity of sixteen and eighteen-wire is given, but no smaller than fourteen is to be used, except in fixture work and in flexible... | |
| Henry Charles Tulley - 1902 - 944 стор.
...The lower limit is specified for rubber-covered wires to prevent gradual deterioration of the high insulations by the heat of the wires, but not from...not taken into consideration in the above tables. Insulation Resistance. — The wiring in any public building must test free from grounds ; ie, the... | |
| |