" a. Must be attached to each side of every overhead circuit connected with the station. It is recommended to all electric light and power companies that arresters be connected at intervals over systems in such numbers and so located as to prevent ordinary... "
Transactions of the American Institute of Electrical Engineers - Сторінка 489
автори: American Institute of Electrical Engineers - 1897
Повний перегляд - Докладніше про цю книгу

Convention

National Electric Light Association. Convention - 1892 - 458 стор.
...combustible material, or separated therefrom by asbestos or cement. LIGHTNING ARRESTERS — Must be : 1. Attached to each side of every overhead circuit connected with the station. 2. In plain sight. 3. On the switchboard or in an equally accessible place, away from combustible material....
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1892 - 188 стор.
...comustible material, or separated therefrom by asbestos or cement. LIGHTNING ARRESTERS—Must be: 1. Attached to each side of every overhead circuit connected with the station. 2. In plain sight. 3. On the switchboard, or in an equally accessible place, away from combustible...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer, Том 17

1894 - 622 стор.
...foot from combutalble material, or separated therefrom by asbestos or cement. Lightning Arretiere. 1. Must be attached to each side of every overhead circuit connected with the station. 2. Must be In plain sight. 8. Must be on the switchboard, or In an equally accessible place, away from...
Повний перегляд - Докладніше про цю книгу

The Electrical Transmission of Energy: A Manual for the Design of Electrical ...

Arthur Vaughan Abbott - 1895 - 646 стор.
...from combustible material, or separated there from by asbestos or cement. 122. LIGHTNING ARRESTERS. 1. Must be attached to each side of every overhead circuit connected with the station. 2. Must be in plain sight. 3. Must be on the switchboard, or in an equally accessible place, away from...
Повний перегляд - Докладніше про цю книгу

The National Electrical Code: An Analysis and Explanation of the ...

Richard Henry Pierce - 1896 - 234 стор.
...separated therefrom by a non-inflammable, non-absorptive, insulating material. 6. LIGHTNING ARRESTERS: — a. Must be attached to each side of every over-head circuit connected with the station, b. Must be mounted on non-combustible bases in plain sight on the switch board, or in an equally accessible...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 208 стор.
...metal frame, it is well to have the frame insulated as the rules indicate. €. Lightning-arresters : a. Must be attached to each side of every overhead circuit connected with the station. 6. Must be mounted on non-combustible bases in plain sight on the switch-board, or in any equally accessible...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1896 - 232 стор.
...separated therefrom by a non-inflammable, non-absorptive, insulating material. 6. LIGHTNING ARRESTERS: — a. Must be attached to each side of every overhead circuit connected with the station. b. Must be mounted on non-combustible bases in plain sight on the switchboard, or in an equally accessible...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 стор.
...separated therefrom by a non-inflammable, non-absorptive, insulating material. 6. LIGHTNING ARRESTERS:— a. Must be attached to each side of every overhead circuit connected with the station. b. Must be mounted on non-combustible bases in plain sight on the switchboard, or in an equally accessible...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 570 стор.
...separated therefrom by a non-inflammable, non-absorptive, insulating material. 6 LIGHTNING ARRESTERS: a. Must be attached to each side of every overhead circuit connected with the station. b. Must be mounted on non-combustible bases in plain sight on the switchboard, or in any equally accessible...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Society of Mechanical Engineers, Том 19

American Society of Mechanical Engineers - 1898 - 1122 стор.
...non-absorptive insulating material. 5. LIGHTNING ARRESTERS — (For construction rules, see No. 55.) a. Must be attached to each side of every overhead...located as to prevent ordinary discharges entering the buildings over the wires connected to the lines. J. Must be located in readily accessible places...