Сховані поля
Книги Книги
" All circuits must be provided with reliable ground detectors. Detectors which indicate continuously, and give an instant and permanent indication of a ground are preferable. Ground wires from detectors must not be attached to gas pipes within the building. "
Transactions of the American Institute of Electrical Engineers - Сторінка 491
автори: American Institute of Electrical Engineers - 1897
Повний перегляд - Докладніше про цю книгу

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 стор.
...device, readily attachable, to afford easy means of testing where the station operates continuously. c. Data obtained from all tests must be preserved for examination by insurance inspectors. These rules on testing to be applied at such places as may be designated by the...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 208 стор.
...continuously. c. Data obtained from all tests must be preserved for examination by insurance inspectors. These rules on testing to be applied at such places as may be designated by the association having jurisdiction. A " series circuit " is one in which everything in the circuit, —...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 570 стор.
...continuously. c. Data obtained from all tests must be preserved for examination by insurance inspectors. These rules on testing to be applied at such places as may be designated by the association having jurisdiction. 8. MOTORS : a. Must be wired under the same precautions as with a...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 568 стор.
...device, readily attachable, to afford easy means of testing where the station operates continuously. c. Data obtained from all tests must be preserved for examination by insurance inspectors. These rules on testing to be applied at such places as may be designated by the...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1896 - 222 стор.
...device, readily attachable, to afford easy means of testing where the station operates continuously. c. Data obtained from all tests must be preserved for examination by insurance inspectors. These rules on testing to be applied at such places as may be designated by the...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 стор.
...device, readily attachable, to afford easy means of testing where the station operates continuously. c. Data obtained from all tests must be preserved for examination by insurance inspectors. These rules on testing to be applied at such places as may be designated by the...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 208 стор.
...device, readily attachable, to afford easy means of testing where the station operates continuously. c. Data obtained from all tests must be preserved for examination by insurance inspectors. These rules on testing to be applied at such places as may be designated by the...
Повний перегляд - Докладніше про цю книгу

Electrical Engineer's Pocket-book: A Hand-book of Useful Data for ...

Horatio Alvah Foster - 1901 - 1018 стор.
...are preferable. Ground wires from detectors must not be attached to gas-pipes within the building. b. Where continuously indicating detectors are not feasible,...must be preserved for examination by the Inspection Deptrtment having jurisdiction. These rules on testing to be applied at such places as may be designated...
Повний перегляд - Докладніше про цю книгу

Standard Wiring for Electric Light and Power: As Adopted by the Fire ...

Harry Cooke Cushing - 1902 - 204 стор.
...are preferable. Ground wires from detectors should not be attached to gas pipes within the building. Where continuously indicating detectors are not feasible,...the circuits should be tested at least once per day (see page 46), and preferably oftener. Data obtained from all tests should be preserved for examination....
Повний перегляд - Докладніше про цю книгу

Practical Lessons in Electricity. Elements of Electricity. The Electric Current

American School (Lansing, Ill.) - 1903 - 320 стор.
...are preferable. Ground wires from detectors should not be attached to gas pipes within the building. Where continuously indicating detectors are not feasible,...the circuits should be tested at least once per day. Data obtained from all tests should be preserved for examination. Storage or Secondary Batteries should...
Повний перегляд - Докладніше про цю книгу




  1. Моя бібліотека
  2. Довідка
  3. Розширений пошук книг
  4. Завантажити ePub
  5. Завантажити файл PDF