" Must be separated from contact with walls, floors, timbers or partitions through which they may pass by non-combustible, non-absorptive, insulating tubes, such as glass or porcelain, except at outlets where approved flexible tubing is required. "
Transactions of the American Institute of Electrical Engineers - Сторінка 492
автори: American Institute of Electrical Engineers - 1897
Повний перегляд - Докладніше про цю книгу

The Architect's and Builder's Pocket-book of Mensuration, Geometry ...

Frank Eugene Kidder - 1892 - 1032 стор.
...of lamps or on hanger boards, cut-out boxes, or the like, •where less distance is necessary. (/) Must be separated from contact with walls, floors,...partitions through which they may pass, by non-combustible insulating tube or hard rubber tube. (g) Must be so spliced or joined as to be both mechanically and...
Повний перегляд - Докладніше про цю книгу

Standard Tables for Electric Wiremen: With Instructions for Wiremen and ...

Charles M. Davis - 1893 - 162 стор.
...structure of lamps or on hanger boards, cut-out boxes, or the like, where less distance is necessary. /. Must be separated from contact with walls, floors,...partitions through which they may pass by non-combustible insulating tube or hard-rubber tube. g. Must be so spliced or joined as to be both mechanically and...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications for the Use of Engineers and Architects

Earle Abbott Merrill - 1896 - 222 стор.
...structure of lamps or on hanger boards, cut-out boxes, or the like, where less distance is necessary. f. Must be separated from contact with walls, floors,...partitions through which they may pass by noncombustible insulating tube. g. Must be so spliced or joined as to be both mechanically and electrically secure...
Повний перегляд - Докладніше про цю книгу

Electric Wiring for the Use of Architects, Underwriters, and the Owners of ...

Russell Robb - 1896 - 206 стор.
...structure of lamps or on hanger-boards, cut-out boxes, or the like, where less distance is necessary. /. Must be separated from contact with walls, floors,...partitions through which they may pass, by noncombustible insulating tube. g. Must be so spliced or joined as to be both mechanically and electrically secure...
Повний перегляд - Докладніше про цю книгу

The National Electrical Code: An Analysis and Explanation of the ...

Richard Henry Pierce - 1896 - 234 стор.
...structure of lamps or on hanger boards, cut-out boxes, or the like, where less distance is necessary, f. Must be separated from contact with walls, floors,...partitions through which they may pass by non-combustible insulating tube. g. Must be so spliced or joined as to be both mechanically and electrically secure...
Повний перегляд - Докладніше про цю книгу

Electric Lighting Specifications

Earle Abbott Merrilol - 1896 - 232 стор.
...structure of lamps or on hanger boards, cut-out boxes, or the like, where less distance is necessary. with walls, floors, timbers, or partitions through which they may pass by noncombustible insulating tube. g. Must be so spliced or joined as to be both mechanically and electrically secure...
Повний перегляд - Докладніше про цю книгу

New Catechism of Electricity: A Practical Treatise

Nehemiah Hawkins - 1896 - 570 стор.
...hanger-boards, cut-out boxes, or the like, where less distance is necessary. f. Must be separated from conctact with walls, floors, timbers or partitions through which they may pass by non combustible insulating tube. WIRING RULES AND REQUIREMENTS. g. Must be so spliced or joined as...
Повний перегляд - Докладніше про цю книгу

Transactions of the American Society of Mechanical Engineers, Том 19

American Society of Mechanical Engineers - 1898 - 1122 стор.
...a conductivity greater than No. 10 B. & S. copper wire, they must be soldered into lugs. All joiuts must be soldered, even if made with some form of patent...nonabsorptive insulating tubes, such as glass or porcelain. Rushings must be long enough to bush the entire length of the hole in one continuous piece, or else...
Повний перегляд - Докладніше про цю книгу

Distributing system and lamps

Francis Bacon Crocker - 1901 - 528 стор.
...binding screws ; and, when they have a conductivity greater than No. 10 B. & S. copper wire, they will be soldered into lugs. All joints must be soldered,...entire length of the hole in one continuous piece, or elsa the hole must first be bushed by a continuous waterproof tube, which may be a conductor, such...
Повний перегляд - Докладніше про цю книгу

Science and Industry, Том 7

1902 - 750 стор.
...smaller size than No. 14 B. & S., except when used for wiring fixtures or by special permission. Wires must be separated from contact with walls, floors,...entire length of the hole in one continuous piece. Transformers must not be placed inside of any building, excepting central stations, unless by special...
Повний перегляд - Докладніше про цю книгу